Refute v0.4.0

Results of the v0.4 pilot

The results of Refute release v0.4.0: a pilot of complete, auditable cases on TESS data. Every case is below, with its verdict from the locked code and the human reading approved by the maintainer, caveats included. Failures and limits are published exactly like everything else.

Method status, as locked in the pilot’s claim: not_validated

In the words of the report: (in English)

No result here establishes a new astrophysical object; no signal is called a planet.

Release page on GitHub · Tracking issue of the phase #177 · Results of v0.2.0

What ran

Known controls, a planet and a false positive, and a funnel of stars with no registered planet candidate (no TOI, no CTOI, no known planet), drawn by a rule fixed in advance. The first stage runs the light-curve tests on every funnel star. The second stage (the pixel files and the full battery) runs on the controls and on the few funnel stars promoted by a cap, drawn at random; eligible stars beyond the cap were not evaluated past the first stage.

Stars run
100
Signal passed the gate
13
Eligible for promotion
5
Promoted to the second stage by the cap
3

Why each funnel star stopped, or went on, after the first stage

Source: report-4.md · Refute v0.4.0

What SURVIVED means here

The pilot’s locked claim gives SURVIVED a narrow meaning. In its words: (in English)

the signal survived the declared decisive battery; temporal confirmation was not required; the method is not validated

Every case that reached the second stage

The verdicts come from the locked code, and no review changes them. Under each one is the human reading of the case: drafted by an agent, checked by a second model and approved by the maintainer. A human reading is an interpretation of the evidence, not a new verdict, and its hypotheses stay hypotheses.

Source text (English)
The verdicts above come from the locked code and no review changes them.
None changes a verdict.

Known planet (control)

TIC-86396382known object: WASP-12 b

Verdict (locked code)
WEAKENED
Signal identity (factor)
yes (1.0)
Temporal diagnostic (blind test by year; never changes the verdict)
pass
Independent review
OBJECTIONS
Reproduction check
OK: manifest intact; key results reproduced
Human reading, approved by the maintainer

The signal matches the known object named above, the planet control, and its identity was recovered at the factor shown above. Caveats: the WEAKENED verdict comes from warnings that do not discriminate the signal; none of the injections into this curve was recovered (see the table below), which does not measure sensitivity; and recovering the signal at that factor only identifies the signal already in the catalogue.

Source text (English)
- **TIC-86396382**: signal matches a known object: WASP-12 b (the planet control); signal identity recovered at factor 1.
Caveat: the WEAKENED comes from warnings that do not discriminate the signal; 0 of 20 injections were recovered on this curve, which does not measure sensitivity; factor 1 identifies the catalogued signal and is not a new confirmation.

Known false positive (control)

TIC-393911494known object: TOI-2106.01

Verdict (locked code)
REFUTED
Signal identity (factor)
yes (1.0)
Temporal diagnostic (blind test by year; never changes the verdict)
pass
Independent review
OBJECTIONS
Reproduction check
OK: manifest intact; key results reproduced
Human reading, approved by the maintainer

The signal matches the known object named above, the false-positive control, and its identity was recovered at the factor shown above. Caveats: this recovers the catalogued signal, but it does not settle whether the signal comes from the target or from a close neighbouring star, nor the physical orbital period. The REFUTED verdict, from “Odd vs. even dips”, stands.

Source text (English)
- **TIC-393911494**: signal matches a known object: TOI-2106.01 (the false-positive control); signal identity recovered at factor 1.
Caveat: factor 1 recovers the catalogued signal; it does not settle whether the signal is on the target or on the neighbor 2.84 arcsec away, nor the physical orbital period; the REFUTED (odd_even) stands.

Funnel star promoted to the second stage

TIC-88096786

Verdict (locked code)
REFUTED
Reason for the verdict
fatal failure in: centroid_shift
Temporal diagnostic (blind test by year; never changes the verdict)
fail
Independent review
SERIOUS OBJECTIONS
Reproduction check
OK: manifest intact; key results reproduced
Human reading, approved by the maintainer

Insufficient data to decide: where the signal comes from is unresolved, because its only fatal failure, in “Where does the dip come from?”, comes from a sector whose measurement may be dominated by artifacts. The deterministic verdict stays REFUTED, the label of the locked battery, by the maintainer’s decision; the reading of this case was set by the maintainer.

Source text (English)
- **TIC-88096786**: insufficient data to decide: the astrophysical origin of the signal is unresolved, because the only fatal failure (centroid_shift) comes from a sector whose measurement may be artifact-dominated.
The deterministic verdict stays REFUTED, the label of the locked battery (the maintainer's decision of 2026-11-01). The conclusion is the human reading of the case: the battery's only fatal failure does not settle where the signal comes from.

Funnel star promoted to the second stage

TIC-286480954

Verdict (locked code)
WEAKENED
Reason for the verdict
warning failure in: plausibility
Temporal diagnostic (blind test by year; never changes the verdict)
inconclusive
Independent review
SERIOUS OBJECTIONS
Reproduction check
OK: manifest intact; key results reproduced
Human reading, approved by the maintainer

Insufficient data to decide: stellar variability is a plausible alternative, supported by the independent review, and the locked battery does not tell it apart well enough from a transit. Caveat: this is a hypothesis; no classification of the star was established. The deterministic verdict stays WEAKENED (the warning from “Physically possible?”).

Source text (English)
- **TIC-286480954**: insufficient data to decide: stellar variability is a plausible alternative supported by independent review; the locked battery does not distinguish it adequately from a transit.
The deterministic verdict stays WEAKENED (the plausibility warning). The conclusion is the human reading of the case.
Caveat: stellar variability is a hypothesis supported by the independent review, with no stellar classification established; the deterministic verdict stays WEAKENED.

A candidate that survived the declared battery

TIC-406413408

Verdict (locked code)
SURVIVED
Reason for the verdict
every test passed (the decisive tests; the temporal diagnostic is not one of them)
Temporal diagnostic (blind test by year; never changes the verdict)
inconclusive
Independent review
SERIOUS OBJECTIONS
Reproduction check
OK: manifest intact; key results reproduced

This is not support for the candidate.

SURVIVED means only that no decisive test failed.

By the independent review’s estimates, several fatal tests lacked the power to fail; Refute has no validated rule for a test’s power. The tests concerned:

  • Bigger window, deeper dip?
  • Where does the dip come from?
  • Hidden second eclipse
  • Odd vs. even dips

Tracked in #185.

The review also found the signal not distinguished from this light curve’s noise or systematics. Tracked in #184.

Source: report-4.md · Refute v0.4.0

Injections and transformed curves

Synthetic transits injected into the curves

Refute injected synthetic transits into the pilot’s light curves, including the controls, before detrending, and counted how many it recovered. This covers the first stage only (the search, the gate and the first-stage tests), not the full battery. Injections into one curve are not independent stars.

Source text (English)
## Injection-recovery per curve (stage 1)
Sampling unit: one injection into that curve; injections into one curve are not independent stars. Across curves the numbers are descriptive only.
- Injection-recovery uses a trapezoid model, injected before detrending, into the pilot's curves only; the numbers are about these curves and this code.

The curves below all carry a signal of their own that passes the gate. On such a curve, a recovered injection only shows that it outranked that signal, because the search keeps one candidate: the rate does not measure sensitivity.

Source text (English)
signal passes the gate (marked *) measures whether an injection outranks that signal, not sensitivity (#180): the search keeps one candidate.
CurveRecoveredInjectionsWilson interval
TIC-863963820200 % – 16 %
TIC-39391149472018 % – 57 %
TIC-88096786162058 % – 92 %
TIC-2864809544208 % – 42 %
TIC-406413408102030 % – 70 %

confidence level of the intervals: 95 %

Over the 87 curves with no gate-passing signal of their own, the median recovery rate was 70 % and the rates ranged from 30 % to 100 %.

Source: report-4.md · Refute v0.4.0

Transformed curves

Each star’s light curve also had inverted copies and copies cyclically shifted in time within each sector. The counts below show how many transformed curves passed the gate and survived each stage’s tests. These counts are descriptive, not a false-alarm rate.

Source text (English)
## Detections on transformed curves (not a false-alarm rate)

Per star: 3 transformed curves (1 inverted, 2 cyclically shifted within each sector).

Funnel, first stage: 300 transformed curves; 64 passed the gate; 17 survived the first stage’s decisive tests.

CaseFirst stageSecond stage
curvespassed the gatesurvived the stage’s testscurvespassed the gatesurvived the stage’s tests
TIC-86396382not run at this stage331
TIC-393911494not run at this stage332
TIC-88096786320320
TIC-286480954330330
TIC-406413408321320

Source: report-4.md · Refute v0.4.0

Independent reviews

Each second-stage dossier was read by its own independent reviewer session. Reviews are observations by a model: none changes a verdict.

Source text (English)
One independent session per stage-2 dossier.
None changes a verdict.

Independent gate reviews of the phase checked its completeness against its acceptance criteria. Their verdicts are about the phase, never about a candidate. Both reports are in Refute’s repository:

Gate reviews of v0.4 (English)

Reproduction and records

Observed

The second-stage dossiers were reproduced in a clean clone of the repository, with a fresh data cache: each check reported the dossier intact and its key results reproduced. That full reproduction is the one on record. The current reproduction instructions, written afterwards, were checked only by a rehearsal of their first step (preparing the inputs), not by a new full reproduction.

Source text (English)
in a clean clone from GitHub at commit 95cd7d9 (CI green), with a fresh data cache.
The full reproduction on record is still the one of 2026-11-01 at `95cd7d9` (annex `reproduction-2`); no new full reproduction was run.
- **The reproduction instructions are the annex `reproduce-4`** (instructions version 4, at commit
rehearsal of `prepare` only, with no change by hand, passed at that commit on 2026-11-02

Source: README.md · Refute v0.4.0

Source text (English)
assembled at P5 (2026-11-01) from dated records: each event's `utc` comes from its source record,
and the hash chain shows the order in which the events were written at P5, not that they were recorded live

The release attaches no files: the dossiers and the inputs are in the Zenodo records above. The data in these records keep the terms of their sources; the release describes them.

Release page on GitHub

Limits

The report lists the limits of this pilot:

SURVIVED means that the declared decisive battery was survived, without requiring the temporal diagnostic to pass. A fatal test can pass without the power to fail, and a surviving signal can be indistinguishable from the curve’s noise.

Source text (English)
- The method is not validated; SURVIVED means the declared decisive battery was survived, without requiring the temporal diagnostic to pass. It is not support for a candidate: a fatal test can PASS without the power to fail (no validated power rule; #185), and a surviving signal can be indistinguishable from the curve's noise (#184).

A pass from the pixel tests does not exclude unresolved blends of stars.

Source text (English)
- A PASS from the pixel tests does not exclude unresolved blends (#187).

No decisive test models stellar variability; the centroid test can be decided by a single sector; a signal that passes the gate can be indistinguishable from the curve’s noise.

Source text (English)
- No decisive test models stellar variability (#182); centroid_shift can be decided by one sector (#183); a gate-passing signal can be indistinguishable from the curve's noise (#184).

Injection-recovery uses a trapezoid model, injected before detrending, into the pilot’s curves only: the numbers are about these curves and this code.

Source text (English)
- Injection-recovery uses a trapezoid model, injected before detrending, into the pilot's curves only; the numbers are about these curves and this code.

The exclusions of known candidates and planets use catalogue snapshots dated 2026-10-29.

Source: report-4.md · Refute v0.4.0

Earlier: v0.2

The second calibration self-claim, with the battery of v0.2, stays published with every target and why it failed.

Results of v0.2.0 →